Nowadays, carpets are widely used as decorative materials in building decoration and public spaces. Their fire performance is directly related to personal safety and property protection. Understanding the core fire performance test indicators for carpets is key to ensuring product safety. This article will explain the core fire performance test indicators for carpets in detail, based on common industry test standards.
CHF (Critical Heat Flux to Extinguishment)
Critical Heat Flux to Extinguishment (CHF) is a core indicator for measuring a carpet's ability to resist sustained combustion. It is defined as the minimum incident heat flux that a material's surface can withstand when the flame stops spreading and finally goes out under the action of a radiant heat source. Its unit is kW/m². The higher the value, the stronger the ability to resist sustained combustion.
FS (Flame Spread)
Flame Spread (FS) refers to the maximum distance that the flame spreads from the ignition source to the surrounding area of the carpet under standard test conditions. Its unit is mm. The smaller the value the lower risk of flame spread during combustion.
Burning Time
Burning time is the duration from when the carpet is ignited to when the flame goes out naturally (or reaches the upper limit of the test duration). The common industry standard requires it to be ≤ 20 seconds. This indicator directly reflects the carpet's "self-extinguishing property" - the ability to go out on its own after being separated from the ignition source. The shorter the time, the better material "self-extinguishing property".
Smoke Production
The test result of total smoke production is expressed in the unit of "%·min" (percentage·minute). The industry standard requires it to be ≤ 750%·min. It is defined as the product of the optical density of the smoke generated by the material during combustion and time, which directly reflects the total smoke released. The smaller the value, the more controllable the concentration and duration of smoke during combustion, making it more conducive to escape.
ASTM E662 Smoke Production Indicators
ASTM E662 is a commonly used international standard for smoke generation testing. It clearly specifies two key smoke optical density indicators at specific time points: smoke optical density at 1.5 minutes (Ds1.5) and smoke optical density at 4.0 minutes (Ds4.0). The qualification requirements are Ds1.5 ≤ 100 and Ds4.0 ≤ 200 respectively. Smoke optical density directly reflects the smoke's light-shielding property - the smaller the value, the thinner the smoke and the higher the visibility.
Burning Charred Area (ASTM D2859)
Burning charred area refers to the spreading range of the charred part of the material within the test frame after combustion. The charred area shall not extend to within 25.4mm (1 inch) of the edge of the frame hole. The core purpose of this indicator is to limit the spread of charred area after combustion, avoid secondary combustion caused by the further spread of the charred area, and reduce the damage of carpet combustion to the ground base and surrounding decorative materials.
Maximum Damage Radius (Chinese Standard)
Maximum damage radius is a key indicator for the scope of carpet combustion damage in Chinese standards. It refers to the maximum radius of the carpet's damaged area after combustion, with the requirement of ≤ 75mm. This indicator complements flame spread distance and charred area, limiting the local damage range caused by combustion from the "radius" perspective. A smaller value means the local damage of the carpet after combustion is lighter, and the post-fire repair cost is also lower.